[© 2004 ZWAGA.COM,  vrij te gebruiken, mits de bron wordt vermeld.]
 

Voorbeel van een RG6 Coax kabel

 

Dit specifieke voorbeeld is een dual-kabel en is 4-voudig afgeschermd.

 

Cable Construction

Center
Conductor
18 AWG Solid Copper
Nominal Diameter: 0.0403"
Dielectric Foam Polyethylene
Nominal Diameter: 0.180"
Inner
Shield
Foil: 0.003" Aluminum Tape
Braid: 34 AWG Aluminum
60% Coverage
Nominal Diameter: 0.212"
Outer
Shield
FOIL: 0.002" Aluminum Tape
BRAID: 34 AWG Aluminum
40% Coverage
Nominal Diameter: 0.232"
Jacket FR-PVC
Cable overall Diameter: (0.300" x 0.630")
Nominal Jacket Thickness: 0.033"

Electrical Properties

Capacitance 16.2 PF./FT. NOM.
Impedance 75.0 +/- 3.0 OHMS
Velocity of
Propagation
84.0% NOM.

Attenuation

Frequency Application dB/100 FT. (NOM)
1 MHz Baseband Video .26 dB
10 MHz Upstream Digital Cable .76 dB
50 MHz TV Ch. 2 1.46 dB
100 MHz FM Radio 2.05 dB
200 MHz TV Ch. 12 2.83 dB
400 MHz CATV Ch. 54 4.05 dB
700 MHz CATV Ch. 109 5.60 dB
900 MHz CATV Ch. 142 6.23 dB
1000 MHz DBS 6.59 dB
1200 MHz DBS 7.50 dB
1450 MHz DBS 8.04 dB
1800 MHz PCS Cell Phones 8.50 dB
2200 MHz Wireless Cable 9.00 dB

[ vorige pagina]